<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-08 00-40-08
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 53 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 3.0 kHz -45 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 18998 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-4,1 dBr 1,13 dBr 2,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Anne-Sophie Mutter (Viulu), Lambert Orkis (piano) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2026.09.08 0.39.05 Total samples: 18998 Equivalent time: 0:15:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 2,7 dBr MIN: -4,1 dBr AVE: 1,13 dBr % above 12,2 dBr: 0,0 Last value: 1,0 dBr (2026.09.08 0.39.05) 00.26 00.28 00.30 00.32 00.34 00.36 00.38 -4 -2 0 2 Pm [dBr]